32
• Indicator
o When Patrol operation starts, Patrol LED is ON with 3 different colors:
o Then e-ion operation starts based on dirtiness level, both Patrol LED and e-ion LED are ON
• Remote Control Receiving Sound
o Normal Operation Î Patrol Mode : Beep
o Patrol Mode Î Stop : Long Beep
o Patrol Mode Î Normal Operation : Beep
o Stop Î Patrol : Beep
• Timer Control
o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol
operation status.
o When ON timer activates during any operation, no change and carry on current operation.
o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is
saved.
• Power Failure Control
o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation
resumes immediately.
o During combination operation, if power failure occurs, after power resumes combination operation resume
immediately.
• Error Detection Control
o The Patrol error detection control starts once the power is supplied to Patrol sensor. However, the error will
display when the Patrol operation is ON.
o Error detection method:
If the Patrol sensor feedback is 0V or 5V continuous for 6 hours, Patrol sensor error occurs. However,
the error will display only when the Patrol operation is ON.
o Patrol Sensor Control after error occurs
During any operation mode combines with Patrol operation
• Power supply to Patrol sensor is OFF
• Air conditioner normal mode operation continues with Patrol LED and Timer LED blinking and “H58”
is indicated.
• Timer LED will always blinking and the Patrol LED continues blinking if the Patrol operation is ON
and stops blinking if the patrol operation is OFF.
During Patrol individual mode
• Power supply to Patrol sensor is OFF
• Patrol LED and Timer LED blinking and “H58” is indicated.
• Timer LED will always blinking and the Patrol LED continues blinking if the Patrol operation is ON
and stops blinking if the Patrol operation is OFF.
•
o Error cancel condition:
Power supply reset
• Patrol Operation Demo Mode
o Patrol Operation Demo Mode start condition
Press “Auto OFF/ON” button at indoor unit for 5 seconds to enter Forced Cooling Operation, then press
“Patrol” button at remote control for 5 seconds and release.
o The Patrol indicator change color every 10 seconds follows the pattern below for demo purpose:
(10 seconds) (10 seconds) " (10 seconds)
Blue
(10 seconds)
Orange
(10 seconds)
Red
o During demo, all operation stops, remote control buttons and auto OFF/ON button are ignored.
o Patrol Operation Demo Mode stop condition
Press “Patrol” button for 5 seconds and release.
Power supply reset.
Patrol LED Air Quality
Blue Clean
Orange Moderate
Red Dirty