125 
17.2.2 Operation mode during Heating Only Operation 
  The table below shows the operation mode comparison when Heating Only Operation Mode Activated and 
Deactivated. 
 
Operation 
Mode 
Heating Only Operation Mode Activated  Heating Only Operation Mode Deactivated 
AUTO 
After 30s sampling, regardless of the indoor intake or 
outdoor intake temperature judgment, the unit will run 
Heating operation. 
After 30s sampling, the unit will judge the operation 
mode base on remote controller temperature setting and 
Indoor Intake Sensor (New Auto Mode) or Outdoor 
Intake Sensor (Old Auto Mode). 
HEAT  The unit will run Heating operation.  The unit will run Heating operation. 
COOL  The unit will stop and Power LED blinking.  The unit will run Cooling operation. 
DRY  The unit will stop and Power LED blinking.  The unit will run Cooling Dry operation. 
NANOE 
Stand-alone 
The unit will stop and Power LED blinking.  The unit will run Nanoe Stand-alone operation. 
Force Cooling 
The unit will run Force Cooling Operation for 
X_CTRYTM [15] minutes 
The unit will run Force Cooling operation. 
Force Heating  The unit will run Force Heating operation.  The unit will run Force Heating operation. 
AUTO 
(with Timer) 
The unit will turn ON by the timer and run Auto 
Operation. After 30s sampling, regardless of the indoor 
intake or outdoor intake temperature judgment, the unit 
will run Heating operation. 
The unit will turn ON by the timer and run Auto 
Operation. After 30s sampling, the unit will judge the 
operation mode base on remote controller temperature 
setting and Indoor Intake Sensor (New Auto Mode) or 
Outdoor Intake Sensor (Old Auto Mode). 
HEAT 
(with Timer) 
The unit will turn ON by the timer and run Heating 
Operation. 
The unit will turn ON by the timer and run Heating 
Operation. 
COOL 
(with Timer) 
The unit will not turn ON by the timer. Power LED 
blinking. 
The unit will turn ON by the timer and run Cooling 
Operation. 
DRY 
(with Timer) 
The unit will not turn ON by the timer. Power LED 
blinking. 
The unit will turn ON by the timer and run Cooling Dry 
Operation. 
Cooling 
Test Mode 
The unit will stop and Power LED blinking. 
The unit will operate according to specify Cooling test 
mode operation parameter. 
Heating  
Test Mode 
The unit will operate according to specify Heating test 
mode operation parameter. 
The unit will operate according to specify Heating test 
mode operation parameter.