78
Cooling Characteristic
[Condition] Room temperature: 27°C (DBT), 19°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
B) Indoor unit capacity: Cooling (2.5 + 4.2), CS-TZ25TKEW + CS-TZ42TKEW
Indoor Discharge Air
Temperature (°C)
Outdoor Air Temperature (°C)
TZ25TKEW TZ42TKEW
12.000
12.630
13.260
13.890
14.520
15.150
15.780
16.410
17.040
17.670
18.300
-10-6-2 2 6 10141822263034384246
Outdoor Air Temperature (°C)
Current
(A)
3.300
4.240
5.180
6.120
7.060
8.000
-10-6-2 2 610141822263034384246
Gas Side Piping
Pressure (MPa)
Outdoor Air Temperature (°C)
0.880
0.904
0.928
0.952
0.976
1.000
1.024
1.048
1.072
1.096
1.120