282
Heating Characteristic
[Condition] Room temperature: 20°C (DBT), 12°C (WBT)
Operation condition: High fan speed
Piping length: 5.0 m
Voltage: 230V, 50Hz
A) Indoor unit capacity: Heating (2.5 + 3.5), CS-Z25TKEW + CS-Z35TKEW
Outdoor Air Temperature (°C)
Indoor Discharge Air
Temperature (°C)
Z25TKEW Z35TKEW
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
26.000
27.300
28.600
29.900
31.200
32.500
33.800
35.100
36.400
37.700
39.000
Outdoor Air Temperature (°C)
Current
(A)
-16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12
7.800
8.260
8.720
9.180
9.640
10.100
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa)
2.200
2.280
2.360
2.440
2.520
2.600
2.680
2.760
2.840
2.920
3.000
-16-14-12-10-8-6-4-2024681012
www.ampair.co.uk | sales@ampair.co.uk