10
Item Unit OUTDOOR UNIT
Type Plate fin configuration forced draft type
Tube Material Copper
Fin Material Aluminium (Blue Coat)
Row / Stage 2 x 46
Heat Exchanger
FPI 19
Air Volume High (Cooling / Heating) m³/min (ft³/min) 60.8 (2146) / 70.1 (2475)
Refrigerant Control Device Expansion Valve
Refrigerant Oil cm
3
FV50S (900)
Refrigerant (R410A) kg 3.40
Dry Bulb Wet Bulb
Maximum °C 46 26
Cooling
Minimum °C -10 -
Maximum °C 24 18
Outdoor Operation Range
Heating
Minimum °C -15 -16
Note
Specifications are subject to change without notice for further improvement.