6
Item Unit OUTDOOR UNIT
Type Plate fin configuration forced draft type
Tube Material Copper
Fin Material Aluminium (Blue Coat)
Row / Stage 2 x 36
Heat Exchanger
FPI 19
Air Volume High (Cooling / Heating) m³/min (ft³/min) 42.5 (1500) / 44.1 (1557)
Refrigerant Control Device Expansion Valve
Refrigerant Oil cm
3
FV50S (900)
Refrigerant (R410A) kg 2.64
Dry Bulb Wet Bulb
Maximum °C 46 26
Cooling
Minimum °C -10 -
Maximum °C 24 18
Outdoor Operation Range
Heating
Minimum °C -15 -16
Note