– 46 –
CS-MA90KE
MAC9509078C2
30 32 34 36 38 40 42 44
OUTDOOR AIR TEMPERATURE (°C)
[Condition] Room temperature: 27/19°C
Cooling operation: At High fan
Piping length: 5 m
8
7
6
5
14
13
12
11
10
0.65
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A) - Cooling Capacity (kW) -
LP: O: Outlet
Gas Side Piping Pressure (MPa) - Air Temperature (°C) -
O
Q
I
L.P
Technical Data
LL
LL
L Operation characteristics
CS-MA120KE / CU-MA240KE
The capability value shown is the value for one unit. For a total for two unit, multiply by 2.
-4 -2 0 2 4 6 8 10
OUTDOOR AIR TEMPERATURE (°C)
[Condition] Room temperature: 20°C
Heating operation: At High fan
Piping length: 5 m
7
6
5
4
44
42
40
38
36
34
1.8
1.7
1.6
1.5
1.4
1.3
5.0
4.5
4.0
3.5
3.0
220V
240V
I: Q:
Current (A) - Heating Capacity (kW) -
HP: O: Outlet
Gas Side Piping Pressure (MPa) - Air Temperature (°C) -
O
Q
I
L.P
1
5
10
15
PIPING LENGTH (m)
[Condition] Room temperature: 27/19°C
Outdoor temperature: 35/24°C
Cooling operation: At High fan
7
6
5
4
13
12
11
10
9
0.60
0.55
0.50
0.45
3.8
3.6
3.4
3.2
3.0
2.8
220V
240V
I: Q:
Current (A) - Cooling Capacity (kW) -
LP: O: Outlet
Gas Side Piping Pressure (MPa) - Air Temperature (°C) -
O
Q
I
L.P
Cooling Characteristic
Heating Characteristic Piping Length Characteristic (Heating)
• Piping Length Characteristic (Cooling)
1
5
10
15
PIPING LENGTH (m)
[Condition] Room temperature: 20°C
Outdoor temperature: 7/6°C
Heating operation: At High fan
7
6
5
4
4.5
4.0
3.5
3.0
2.5
1.9
1.8
1.7
1.6
46
44
42
38
36
220V
240V
I: Q:
Current (A) - Heating Capacity (kW) -
HP: O: Outlet
Gas Side Piping Pressure (MPa) - Air Temperature (°C) -
O
Q
I
L.P
Untitled-6 6/30/00, 8:19 AM46