8.3.1.1. Indoor unit
There should not be any heat source of steam near the unit.
There should not be any obstacles to prevent the air
circulation.
A place where air circulation will be good.
A place where drainage can be easily obtained.
A place where noise prevention is taken into consideration.
Do not install the unit near the doorway.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
From the floor, the height should be more than eye-level.
8.3.1.2. Outdoor unit
If an awning is built over the unit to prevent direct sunlight
or rain exposure, be careful that heat radiation from the
condenser is not restricted.
There should not be ary animals or plants which could be
affected by hot air discharged.
Ensure the spaces indicated by arrows from the wall,
ceiling, fence, or other obstacles.
8.3.1.3. Piping lenght and elevation
Piping size Max piping Max
Model Gas Liquid length elevation
(m) (m)
CS-
SA9CKP/CU-
SA9CKP5
3/8” 1/4” 7 5
CS-
SA12CKP/CU-
SA12CKP5
1/2” 1/4” 7 5
8.3. Installation of indoor, outdoor unit
8.3.1. Select best location
28
CS-SA9CKP CU-SA9CKP5 / CS-SA12CKP CU-SA12CKP5