20
4The lower limit setting ‘ ’ or the upper limit setting
‘ ’ will be displayed.
4-5.
Threshold Value Fine Adjustment Mode [when using FX-305(P) window comparator mode]
This mode allows fine adjustment of the ‘Threshold value (1_SL, 2_SL)’ setting.
1 Press the [MODE key] twice to select ‘threshold value fine
adjustment mode’.
2 Turn the [Jog switch] to set ‘output 1’.
3 Press the [Jog switch] to select ‘output 1’.
5 Turn the [Jog switch] to select ‘1_SL’. If the [Jog switch] is
pressed, the threshold value for ‘1_SL’ will be displayed.
If an increased ‘threshold value’ is desired,
turn the [Jog switch] toward the ‘
’ direction.
If a decreased ‘threshold value’ is desired,
turn the [Jog switch] toward the ‘
’ direction.
6 If the [Jog switch] is pressed, the display will blink quickly
3 times and the threshold value for ‘1_SL’ will be confirmed.
7 ‘ ’ is displayed. If the [Jog switch] is turned, then the
upper limit setting ‘ ’ will be displayed.
Turn the Jog switch to set
the desired threshold value.
Press the
Jog switch.
Press the
Jog switch.
Press the
MODE key twice.
Turn the Jog switch to select either
upper limit or lower limit.
Turn the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Output 1
To be continued on the next page
Refer to p.21
for 2_SL settings.
Select ‘1_SL’.
Setting for 1_SL
The digital display will quickly
blink 3 times to confirm the value.
In case of
changing
threshold value
to 85.