Supplementary Data 2 Reason
1 S-reel pulse is less than 3 when the loading has been completed.
(Miss catching the tape)
2 Pulse Timer over during the short rewind at the DOWN position.
(Error of S-photo sensor system, S-reel system, Capstan system)
3 Mechanism lock from the DOWN position to the LOAD position during the
loading.
4 Both ends have been detected at the LOAD position when the loading is
started.
13. Assembling and Disassembling
13.1. Disassembly Flow Chart
The following chart is the procedure for disassembling the casing and inside parts for internal inspection when carrying out the servicing.
To assemble the unit, reverse the steps shown in the chart below.