64
UF-9000
JUN 2004
Ver. 2.0
DP-180/190
4.1.4. F5 Mode: Function Parameters (For Copier)
Set the machine to Service Mode and press "5" key on the Keypad.
Press the "START" key.
Enter the desired code number or press “V”, ”/\” arrow keys.
Press the "SET" key.
Enter the desired function code number and press “SET” key.
When the “CLEAR” key is pressed, the selected code input will not be accepted.
Press “STOP” key, then press “FUNCTION” and “CLEAR” keys simultaneously to exit the service mode.
Reboot the machine after setting the parameter(s) to activate the setting(s).
F5 Mode
No. Item Function Default Setting
00 Not Used
01 Frequency Desired 0 : Auto
1 : 50 Hz
2 : 60Hz
2 (for USA / Canada)
1 (for Europe)
02-03 Not Used
04 LSU Off Timer 1 : 5 sec.
2 : 10 sec.
3 : 15 sec.
4 : 20 sec.
6 : 30 sec.
8 : 40 sec.
10 : 50 sec.
12 : 60 sec.
1
05-09 Not Used
10 Exit Tray Limitation
(Up to 150 Sheets)
0 : None
1 : Accumulate
2 : Job
0
(Effective from June
2004 Production)
11-12 Not Used
13 Paper Out Red Indicator 0 : On
1 : Off
0
14 Paper Size (Tray 1)
(UF-9000)
4 : A4-R
12 : LEGAL
14 : LETTER-R
14 (for USA / Canada)
4 (for Europe / Others)
Paper Size (Tray 1)
(DP-180/190)
4 : A4-R
6 : B5-R
8 : A5-R
12 : LEGAL
14 : LETTER-R

Other manuals for Panasonic DP-190