4.2.5.2. Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Press the “V”, ”/\” arrow keys to select the "4: MODEM Test" on the display.
Press the “SET” key to select the "2: Tonal Testl".
Press the “SET” key.
Press the desired number and press the "START" key.
Press the “STOP” key twice to exit the service mode.
Tonal Signal Table
Number Signals
1 462 Hz
2 1080 Hz
3 1100 Hz
4 1300 Hz
5 1650 Hz
6 1850 Hz
7 2100 Hz