Electrical Connection Electrical Connection
39
Inverter communication terminal (Purchase separately)
38
No.
4
Port Pin
Pin 1: RS485_METER_A
Pin 2: RS485_METER_B
Pin 3: GND
Pin 5: DRM0
Pin 4: +12V_RELAY_OUT
Pin 8: STOP_NO-
Pin 7: STOP_NO+
Pin 6: +12V_COM
AUX terminal
5
6
Pin 1: SYSR_L
Pin 2: SYSR_H
Pin 3: CAN_L
Pin 5: RS485_BI_A
Pin 4: CAN_H
Pin 8: GND
Pin 7: +12V
Pin 6: RS485_BI_B
Pin 1: SYSR_L
Pin 2: SYSR_H
Pin 3: CAN_L
Pin 5: RS485_BI_A
Pin 4: CAN_H
Pin 8: GND
Pin 7: +12V
Pin 6: RS485_BI_B
Terminals
Pin 1: GND
Pin 2: RS485_MLPE_A
Pin 3: RS485_MLPE_B
Type
CAT5 or
better
CAT5 or
better
CAT5 or
better
CAT5 or
better
Cross-sectional Area Range
24-18 AWG
24-18 AWG
18-16 AWG
24-18 AWG
18-16 AWG
24-18 AWG
7
COMM in
terminal
COMM out
terminal
MLPE terminal
NOTE!
The strip length of the terminals is 0.24 in / 6 mm. The torque is 1.8
in-lbs / 0.2 N·m.
Ÿ Required wire size and torques
Inverter power terminal (Purchase separately)
2
3
5 6
1
4
7
1
2
3
153.6
12-8 AWG (3.8KW),
8 AWG
No.
90°C(194°F), 600V, copper
90°C(194°F), 600V, copper
90°C(194°F), 600V, copper
0.47 in/12 mm
10-8 AWG
Cross-sectional Area Range
Strip Length
Terminals
PV terminals
AC terminals
Ground terminals
Type
0.47 in/12 mm
0.47 in/12 mm
10-8 AWG (5/6/7.6KW)