8
<Installation interval for EX-13□,EX-17□>
In case using at sensing distance (L3) 500mm, the
operation point (ℓ3) is approx. 76.6mm according to
diagram above.
The installation interval is
Approx. 76.6mm × 2 = approx. 153.2mm
Thus, install approx. 153.2mm or more away
<Installation interval for EX-13E□,EX-17E□>
In case using at sensing distance (L4) 500mm, the
operation point (ℓ4) is approx. 50mm according to dia-
gram above.
The installation interval is
Approx. 50mm × 2 = approx. 100mm
Thus, install approx. 100mm or more away.
EX-13E□,EX-17E□: approx. 100mm or more
EX-13E□,EX-17E□: approx. 100mm or more
500mm
Emitter Receiver
Thru-beam type: EX-13□, EX-17□ parallel deviation diagram (typical)
100 50 0 50 100
(ℓ3)
(L3)
0
800
400
600
200
Thru-beam type: EX-13E□, EX-17E□ parallel deviation diagram (typical)
100 50 0 50 100
(ℓ4)
(L4)
0
800
400
600
200
Sensing distance L (mm)
CenterLeft
Right
Operating point ℓ (mm)
Sensing distance L (mm)
CenterLeft
Right
Operating point ℓ(mm)