NOTE:
• When the remaining time prior to the
tightening time is less than 1 hour, the
display will alternate between the “set
value” and “-1”.
If the current tightening time remains
unchanged and the inspection duration
is extended, the new set value must be
greater than the current one.
When it reaches the set time, the
display alternates between the set
value and 0.
Buzzer setting
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
You can select from three buzzer modes.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the A button twice.
The current setting value will be displayed.
3. Press the and buttons to set the
desired value.
Display Function
b0 No buzzer
b1
Buzzer accompanying green indicator
b2 Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
NOTE:
The tool ships with the buzzer mode set to
b0 by default.
LED light setting
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
You can select from two LED light modes.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the B button once.
The current setting value will be displayed.
3. Press the and buttons to set the
desired value.
Display Function
d1 Linked to LED light button
d2 Linked to trigger switch operation
4. Press the OK button to accept the new
setting.
NOTE:
The tool ships with the LED light mode set
to d1 by default.
Speed control function
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
The speed (RPM) can be changed with the
amount of depression of the trigger.
1. Set the tool to setting configuration
mode. (See page 18.)
2. Press the B button three times.
The setting value will be displayed.
3. Press the and buttons to set the
desired value.
Operation Function
P0 Speed control ON
P1 Speed control OFF
4.
Press the OK button to accept the new
setting.
Setting the undetect time
(EYFLA7, EYFLA8, EYFLA9,
EYFMA2)
To set the time to undetect the function of
“snug point detection level” from the start
tightening, do as follows.
1. Set the tool to the configuration mode.
(See page 18.)
2. Press button A three times.
•
The current set value is displayed, and the
main unit panel starts flashing.
Display: J0 ashing.
Battery capacity indicator: The upper and
lower bars ash.
[Fig.31]
3. Press and buttons as required to
change the time.
Operation Display Seconds
30 3
1 0.1
J0 OFF
4. Press the OK button to accept the new
setting.