6
6
Setting Default setting Description
Response
speed
Set the response time.
”: High precision 10ms
”: Standard 5ms
”: High speed 1.5ms
Output
operation
Select the control output operation mode.
”: Light-ON, “ ”: Dark-ON
Sensing
output
Set the sensing output.
”: Normal sensing mode
”: 1-point teaching (Window comparator
mode)
”: 2-point teaching (Window comparator
mode)
”: 3-point teaching (Window comparator
mode)
”: Rising di󰀨erential mode
”: Trailing di󰀨erential mode
Hysteresis
HG-C1030L3-P:
HG-C1050L3-P
HG-C1100L3-P:
HG-C1200L3-P:
HG-C1400L3-P:
Set the hysteresis width.
HG-C1030L3-P: 0.001 to 5.00mm
HG-C1050L3-P: 0.01 to 15.00mm
HG-C1100L3-P: 0.02 to 35.00mm
HG-C1200L3-P: 0.1 to 80.00mm
HG-C1400L3-P: 0.2 to 200.00mm
Shift
amount
HG-C1030L3-P:
HG-C1050L3-P
HG-C1100L3-P:
HG-C1200L3-P:
HG-C1400L3-P:
Set shift amount of threshold value in limit
teaching.
Set the shift amount to a value that is twice the
value of hysteresis or more.
HG-C1030L3-P□: 0.002 to 10.00mm
HG-C1050L3-P□: 0.02 to 30.00mm
HG-C1100L3-P□: 0.04 to 70.00mm
HG-C1200L3-P□: 0.2 to 160.0mm
HG-C1400L3-P□: 0.4 to 400.0mm
Timer
Set the timer operation. The timer time is xed
at 5ms.
”: No timer,
”: OFF-delay timer
”: ON-delay timer
”: One-shot timer
Timer
period
Set the timer period when the timer setting is
set to “OFF-delay timer,” “ON-delay timer” or
“One-shot timer.”
”: 5ms, “ ”: 10ms, “ ”: 25ms,
”: 50ms, “ ”: 100ms, “ ”: 250ms,
”: 500ms, “ ”: 1,000ms, “ ”:
5,000ms
Display
The display of the measured value can be
changed.
”: Normal
”: Invert
”: O󰀨set
Hold
Set the control output and the analogue output
operation when a measurement error occurs
(insu󰀩cient light intensity, saturation of light
intensity, out of measurement range).
”: Hold OFF
”: Hold ON
ECO
The digital display can be set to go OFF when
key operation is not performed for 30 seconds.
Current consumption can be reduced.
”: ECO OFF
”: ECO ON
Reset
Return to the default setting (factory setting).
”: Reset NG
”: Reset OK
Procedure
Measurement display
DOWN: Press for 3 seconds
Response
time setting
High precision High speedStandard
Output operation
setting
Light-ON Dark-ON
Trailing differential
mode
Rising differential
mode
2-point teaching
(Window comparator
mode)
1-point teaching
(Window comparator
mode)
Normal sensing
mode
Sensing output
setting
3-point teaching
(Window
comparator mode)
Hysteresis setting
Hysteresis width
UP key: Increases the hysteresis width
DOWN key: Decreases the hysteresis width
Timer setting
No timer
OFF-delay ON-delay One-shot
Display setting Normal
Invert Offset
Hold setting Hold OFF
Hold ON
ECO setting
ECO OFF
ECO ON
Reset setting
Reset NG
Reset OK
Response
time setting
UP key: Increases the shift amount
DOWN key: Decreases the shift amount
Shift amount setting
UP key: Increases the timer period setting
DOWN key: Decreases the timer period setting
Timer period setting (only when “OFF-delay”, “ON-delay” or “One shot” is set for “Timer setting”)