7
13
Error indication
In case of error, attempt the following measures.
Error
indication
Description Solution
Hold OFF
- - - -
Hold ON
Measured
value blinks
Insu󰀩cient amount of reected
light.
The sensing object is out of
the sensing range.
Conrm that the sensing distance
is within the specication range.
Adjust the installation angle of the
sensor.
Nonvolatile memory is
damaged or passed its life
expectancy.
Please contact our o󰀩ce.
Load of the sensing output
is short-circuited causing an
over-current to ow.
Turn OFF the power and check
the load.
The semiconductor laser is
damaged or passed its life
expectancy
.
Please contact our o󰀩ce.
When zero set is set, the
measurement is not performed
normally.
Since the display setting is set
to “O󰀨set”, the zero set func-
tion can not be used.
Conrm that the sensing distance
is within the specication range.
Set the display to any setting
except “O󰀨set.
During teaching, the mea-
surement is not performed
normally.
Conrm that the sensing distance
is within the specication range.
System error Please contact our o󰀩ce.
14
Cautions
This product has been developed / produced for industrial use only.
Make sure that the power supply is OFF before starting the wiring.
If the wiring is performed incorrectly, it will cause a failure.
Do not run the wires together with high-voltage lines or power lines,
or put them in the same raceway. This can cause malfunction due to
induction.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to
an actual ground.
If noise generating devices (switching regulators, inverter motors, etc.)
are used around the sensor mounting area, make sure to connect the
frame ground (FG) terminal of the device.
Do not use this product during the transient state when the power sup-
ply is turned ON.
The overall length of the cable can be extended to 20m maximum with
a cable size of min. 0.3mm
2
.
Make sure that stress by forcible bend or pulling is not applied to the
sensor cable joint.
Although it depends on the type, light from rapid start type or high
frequency lighting type, uorescent lights, sunlight and etc. may a󰀨ect
the sensing, therefore make sure to prevent direct incident light.
This product is suitable for indoor use only.
Keep water, oil, ngerprints and etc. which reect light, dust or par-
ticles etc. which interrupt the light, away from the emitting / receiving
surfaces of this product. If contaminants adhere to the surface, wipe
o󰀨 with a dust-free soft cloth, or lens cleaning paper.
Do not use the sensor in locations where there is excessive vapor, dust
or etc. or in an atmosphere where corrosive gases, etc. are generated.
Take care that the product does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid or alkaline.
Make sure to turn OFF the power supply, before cleaning the light
emitting / receiving windows of the sensor head.
There is a certain deviation in the directionality of this product. Install
the product using a mounting bracket or similar tting to allow the
adjustment of optical axis.
The internal memory (nonvolatile) of this product has a service life.
Settings cannot be congured more than 100,000 times.