4
Stable sensing is not possible.
3-point teaching (window comparator mode)
This is the method to perform 3-point teaching (P-1, P-2, P-3) and to set the
threshold range by setting threshold 1_SL in the mid-point between the 1st
time and 2nd time, and threshold 2_SL in the mid-point between the 2nd
time and 3rd time as shown in the following gure.
When performing 3-point teaching (window comparator mode), preset “Win-
dow comparator mode 3” in the sensing output setting of the PRO mode.
For the setting method, refer to section 13, “PRO mode setting.”
When performing teaching, use sensing objects (P-1, P-2, P-3) with dier-
ent distance.
After teaching, P-1, P-2 and P-3 will be automatically rearranged from the
smaller value.
P-1 P-2 P-3
Threshold 1_SL
Threshold 2_SL
3rd time
2nd time
1st time
ON
OFF
OFF
1. Press the TEACH key when the sensing
object P-1 is present (1st time).
(System command / Index2: 0x4D)
2. Press the TEACH key when the sensing
object P-2 is present (second time).
(System command / Index2: 0x4D)
3. Press the TEACH key when the sensing
object P-3 is present (3rd time).
(System command / Index2: 0x4D)
Stable sensing is possible.
Stable sensing is not possible.
Span adjustment in ‘Rising dierential mode’ or ‘Trailing dierential
mode’
This mode is used to cancel the gradual changes in the measured values
and to only detect sudden changes.
To use the Rising dierential mode or Trailing dierential mode, preset ‘Ris-
ing dierential mode’ oder ‘Trailing dierential mode’ in the sensing output
setting of the PRO mode.
For the setting method, refer to section 13, “PRO mode setting.”
The threshold can be set by using the threshold value ne adjustment func-
tion, see section 9, “Threshold value ne adjustment function”.
1. Press the TEACH key.
2. Press the UP key or DOWN key to select
the span.
3. Press the TEACH key to set the span.
9
Threshold value ne adjustment function
● The ne adjustment of the threshold can be performed in the measure-
ment display.
● The ne adjustment of the threshold can be performed even after
teaching.
‘Normal sensing mode’, ‘Rising dierential mode’ and ‘Trailing dif-
ferential mode’
Confirmed
TEACH key
UP/DOWN key
(automatically
set after 3
seconds.)
Window comparator mode
When the sensing output is set to window comparator mode, the display
and can be changed only by pressing the TEACH key for 1s.
Automatic
Press the TEACH
key 1 second
Change the
threshold value
display
When performing a ne adjustment of the threshold of or ,
press the UP key or DOWN key. After or is displayed, the ne
adjustment of the threshold can be performed.
Confirmed
Automatic
(automatically
set after 3
seconds.)
TEACH key
Press the
UP/DOWN key
Press the
UP/DOWN key
or
t span Long span