When there is a step in the moving object, mount the product as fol-
lows. The e󰀨ect of reection deviation by the edges of the steps can
be minimized by mounting the sensor in the correct direction.
When measuring in narrow locations or inside holes, mount the prod-
uct so that optical path from the light emitting part to light-receiving
part is not interrupted.
Mount the sensor to a wall as follows, so that the multiple light reec-
tions on the wall do not reach the light-receiving part. When the reec-
tion factor on the wall is high, it is e󰀨ective to use a dull black color.
6
I/O circuit diagrams
As a general-purpose sensor
Connected to a IO-Link master
Terminal arrangement of M12 connector
Note: When the product is used as a general-purpose sensor, the
IO-Link communication output (C/Q) provides the same output
operation as the control output (DO).
7
List of functions
Function
Setting on main unit
IO-Link communication setting
Teaching
Teaching input Index2
Limit-teaching (UP key) Index2
Limit-teaching (DOWN key)
Index2
Teaching cancel Index2
Sensing output
setting
Normal sensing mode
Window comparator mode
(1/2/3-point)
Di󰀨erential mode
Index61_2
Threshold setting
Threshold 1_SL Index60_1
Threshold 2_SL Index60_2
Di󰀨erential mode
Span setting Index67_1
Threshold setting Index67_2
Peak / Bottom hold
function
Setting Index84
Release Index2
Zero set function
Save in nonvolatile memory Index2
Execute Index2
Release of nonvolatile memory Index2
Key lock function Setting / Release Index12
Response Speed Setting
10ms / 5ms / 1.5ms
Index66
Output operation setting
Light-ON / Dark-ON
Index61_1
Hysteresis setting
Hysteresis value Index61_3
Shift setting Mode Index74_1
Shift amount setting
Shift amount Index74_2
Timer setting Timer mode Index64_1
Timer period setting
Timer period Index64_2
Display setting
Normal / Invert / O󰀨set
Index83
Hold setting ON/OFF Index85_1
ECO setting ON/OFF Index80
Reset setting Execute Index2
Emission halt - Index70
Instability detection
threshold
- Index160
Instability detection
delay time
- Index162
Operating time - Index163
Number of data
save operations
- Index164
Notication ag
setting
- Index168
Notication event code
- Index169
Note: For the IO-Link communication setting, refer to the attached sheet,
“Index list”
IMJE-HGCINDEXV1EN 09/2018.
8
Teaching
2-point teaching
This method is the basic teaching method.
1
2
Distance
Background Sensing object
Threshold
ON
OFF
1. Press the TEACH key when the back-
ground is present.
(System command / Index2: 0x4D)
This product IO-Link master
(Brown / 1) +V
+V
(Black / 4) C/Q
C/Q
(White / 2) DO
DI
(Blue / 3) 0V
0V
(Brown / 1) +V
(Black / 4) C/Q (Note)
(White / 2) DO
(Blue / 3) 0V
Load
Load
+
-
24V DC
±10%
1
4
2
3
Terminal No. Terminal name
1 +V
2 Control output (DO)
3 0V
4 IO-Link communication (C/Q)
Recommended extension cable with connectors on both ends