8
Panasonic Industrial Devices SUNX Co., Ltd.
http://panasonic.net/id/pidsx/global
Overseas Sales Dept. (Head O󰀩ce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Telefon: +81-(0)-568-33-7861 FAX: +81-568-33-8591
Europe Headquarter: Panasonic Electric Works Europe AG
Robert-Koch-Straße 100, D-85521 Otttobrunn, Germany
Telefon: +49-89-45354-1000
15
Specications
Discrete wire
HG-
C1030L3-P
HG-C1050L3-P HG-C1100L3-P
HG-
C1200L3-P
HG-C1400L3-P
M12 connector
HG-
C1030L3-P-J
HG-C1050L3-P-J
HG-C1100L3-P-J
HG-
C1200L3-P-J
HG-C1400L3-P-J
Measurement center
distance
30mm 50mm 100mm 200mm 400mm
Measurement range ±5mm ±15mm ±35mm ±80mm ±200mm
Repeatability 10µm 30µm 70µm 200µm
300µm
(measurement distance 200 to 400mm)
800µm
(measurement distance 400 to 600mm)
Linearity ±0,1% F.S. ±0,2% F.S.
±0,2% F.S.µm
(measurement distance 200 to 400mm)
±0,3% F.S.
(measurement distance 400 to 600mm)
Temperature charac-
teristic
0.03%F.S./°C
Beam diameter
3
≈ 50µm ≈ 70µm ≈ 120µm ≈ 300µm ≈ 500µm
Light source
Red semiconductor laser class 2 (JIS / IEC / FDA
2
)
Max. output: 1mW, emission peak wavelength: 655nm
Supply voltage 24V DC ±10% including ripple max. 10% (P-P)
Power consumption Max. 40mA (at 24V DC supply voltage)
Control Output
PNP open-collector transistor
Maximum source current: 50mA
Applied voltage: same as supply voltage (between control output to +V)
Residual voltage: max. 1.5V (at 50mA source current)
Leakage current: max. 0.1mA
Output operation Selectable either Light-ON or Dark-ON
Short-circuit
protection
Incorporated (auto-reset)
Response time Switchable between high speed (1.5ms), standard (5ms), and high precision (10ms)
IO-Link communication
IO-Link specication: Ver1.1
Baud rate: COM3 (230.4kbps)
Process data length: 4byte
Degree of protection IP67 (IEC)
Degree of pollution 2
Ambient temperature
-10 to +45°C (no dew condensation or icing allowed)
Storage: -20 to +60°C
Ambient humidity 35 to 85% RH, at storage: 35 to 85% RH
Ambient illumination 3000ℓx max. (Illumination level of light receiving surface under incandescent light)
Operating altitude Max. 2000m
4
Cable
Discrete wire: 0.2mm
2
4-core PVC cable, 2m long
M12 connector: 0.2mm
2
4-core PVC cable, 0.3m long with connector
Material Enclosure: die-cast aluminum, front cover: acrylic
Weight
35g (without cable), 85g (including cable)
Applicable standards EMC Directive
1
Measurement conditions: 24V supply voltage, 20°C ambient temperature, 10ms response time. The subject is white ceramics.
2
This is based on the FDA Standard, according to Laser Notice No. 50 of the FDA Standard
3
This is the size in the measurement center distance. These values were dened by using 1/e
2
(approx. 13.5%) of the center light intensity. Due to leak light
outside the specied area, the reectance around the detecting point may be higher than at the point and this may a󰀨ect the measurement value.
4
Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0m

Related product manuals