Items Adjustment
Point
Procedure
(J)
*
Transmitted
Power
Confirmation
- Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
-Test mode: PP
-RFPI: 0102030408
-Traffic Carrier: 5
-Traffic Slot: 4
-Mode: Loopback
-RF LEVEL = -70dBm
2. Execute the command "regcmd60 01 02 03 04 08".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at A201 (TP15) is 20dBm ~ 25dBm.
(K)
*
Modulatoin
Check and
Adjusment
- Follow steps 1 to 3 of (J) above.
4.Confirm that the B-Field Modulation is 360kHz/div ~ 380kHz/
div using data type Fig 31.
5.Adjust the B-Field Modulation if required. (Execute the
command "Readmod" and "wrtmod xx", where xx is the
value.)
(L) Frequency
Offset
Confirmation
- Follow steps 1 to 3 of (J) above.
4.Confirm that the frequency Offset is -50kHz ~ +50kHz.
68