Initial Type Description
F The data initialized by only F command
0 The data initialized by F and 0 command
1 The data initialized by F, 0 and 1 command
2 The data initialized by all command (F,0,1,2)
Country
Setting
Description
x Default - no specific country setting, so revert to default value.
28.3. EEPROM contents
28.3.1. General Setup
AddressInitial
Type
Name Description Default
52 F EEP_Ipei International Portable Part Equipment
Identities.
A concatenation of an EMC and a unique 20
bit Serial Number.
0x00,0x00
57 F EEP_FreqTrim_L Setting value of FREQ_TRIM_REG 0x75
58 F EEP_BandGap Setting value of BandGap REG 0x08
6B 1 EEP_LowQualityLevel Signal quality level at which handover is
initiated(CRC error count).
0x10
74 1 EEP_RxMuteSyncError Continuous SYNC error times for the Rx
Mute(0-0xFF:Error times).
0x10
131 0 EEP_HandsetNumber HandsetNumber each Subscription.
(wordx4subs)
99