14.2. Adjustment Standard (Cordless Handset)
When connecting the Simulator Equipments for checking, please refer to below.
Note:
(A) - (U) is refered to ADJUSTMENTS (CORDLESS HANDSET) ()
15. RF SPECIFICATION
15.1. Base Unit
Item Value Refer to -. *
TX Power 20 dBm ~ 25 dBm
Adjustment (Base Unit) (I)
Modulation 360 kHz/div ~ 380 kHz/
div
Adjustment (Base Unit) (J)
Data type:
Frequency Offset -50 kHz ~ +50 kHz
Adjustment (Base Unit) (K)
RX Sensitivity < 1000 ppm
Adjustment (Base Unit) (M)
Timing Accuracy -2.0 ppm ~ +2.0 ppm Adjustment (Base Unit) (N)
RSSI Level 0x11 (hex) ~ 0x25 (hex) Adjustment (Base Unit) (O)
* : Refer to Adjustment (Base Unit) ()
15.2. Cordless Handset
72