2.6 Hardware (H/W) Settings
Programming Guide 145
2 Check desired ports in the left table in the Edit Multiple Ports dialogue box.
(Click Select All or Clear All as needed, then select/deselect the desired ports.)
3 Edit parameters in the right table in the Edit Multiple Ports dialogue box.
4 Click OK.
Port #01 – #24
Specifies the parameters for each port.
Compression Mode
Specifies the algorithm used to convert analogue and digital signals.
Value Range
Mu-Law, A-Law
Gain for Input Signal
Specifies the input signal gain.
Value Range
-8–+2 dB
Gain for Output Signal
Specifies the output signal gain.
Value Range
-2–+8 dB
DTMF Detection Sensitivity
Specifies the DTMF detection sensitivity.
Value Range
-5– -20 dBm
DTMF Detection Standard Twist Level
Specifies the DTMF detection standard twist level.
Value Range
0–9.0 dB, Units 0.1 dB
DTMF Detection Reverse Twist Level
Specifies the DTMF detection reverse twist level.