Loading...
- 25 -
NA-FS80X1 / FS90X1
Display Part
An abnormal
Contents
Detected Contents
When communication control is
abnormal between a controller for
load and a controller for indication.
Pull a power plug out.Communication
line disconnection
is abnormal.
• Breaking communication line or
connector contact error.
• Replace a controller of the load
side or display side.
• Replacement of the water supply
valve.
• Check output and replacement of
the load side controller.
A check procedure /
Measures
A cancellation
Method
When a water level sensor detects
overflow water level more than
constant time.
Push [power off]
button.
Overflow water
is abnormal.
Operate geared motor for drainage
and drain water.
• Check disconnected connector of
geared motor and adjustment.
• Passable check and replacement
of the geared motor.
• Check input and output of the load
side and replacement controller.
For details refer to a clause of
[trouble diagnosis of H25, H26].
When geared motor doesn’t work
normally even if it passes from the
start of the drainage work
sequence for 3 minutes.
Push [power off]
button.
Geared motor
for drainage is
abnormal.
When an opening and shutting of
geared motor (drainage valve)
isn’t normal, it does not change
even if it is controlled to become
normal.
• Check disconnetion of geared
motor connector and adjustment.
• Passable check and replacement
of the geared motor.
• Check input and output of the load
side and replacement controller.
For details refer to a clause of
[trouble diagnosis of H25, H26]
• Check disconnetion of a connector
• Passable check and replacement
of the door lock switch
• Check output from a load side
controller and replacement.
When geared motor doesn’t work
normally at the time of pulsator
churning.
Push [power off]
button.
Clutch is
abnormal.
In the case it does not drive even
if there is output to a cover lock
switch.
• Check if too much cloths in a
washing tank.
• Check cloths or waste thread filter
are caught in an inner cover.
• Check connector disconnection of
a motor and the rotary sensor.
• Replacement of the machine
motor.
• Check output from a load side
controller and replacement.
Push [power off]
button
A door lock
switch is
abnormal.
When the signal of the rotary
sensor doesn’t input at the time of
a washing rotate for 2 minutes.
Push [power off]
button.
Overloading.
• Check the power supply voltage.Input voltage exceeds 120V. Auto-off.High voltage.
• Check the power supply voltage.Input voltage is lower than 65V. Push [power off]
button.
Low voltage.
• Replace a controller of the load
side.
• Check short circuit of a coil and
replacement of a bath pump or the
machine motor.
When overcurrents more than 8A
flow in circuit of inverter 1.
Push [power off]
button.
Inverter circuit
overcurrent.
• Check operation of the machine
motor.
• Replace a controller of the load
side.
When a demagnetization electric
current detection circuit works
more than the predetermined
number of times.
Push [power off]
button.
Abnormal
demagnetization
electric current
in machine motor.