7.5SimplewayofH.V.Inverter/magnetron
troubleshooting
Purpose:
Simpleway(3/23secondsrule)ofidentifyingwhetherit’sMagnetron,Inverterorothers.
Setup:
TheunitunderquestionisconnectedthroughtheAmmeterasshownbelow.
Procedure:
Followthematrixtablebelowtoidentifytheproblemsource.
Note:
DonotreplacebothInverterboardandMagnetronsimultaneouslyandautomaticallywithoutgoingthroughthisprocedure.
Powerwill:
Ammeter
readingis:
Todo: Remedy:
Powerwill:
Ammeter
readingis:
Todo: Remedy:
Shut off in 23
secondsafter“Start”.
1.Between 0.5A
and1.0A.
Checkandrepairopenmagnetroncircuit
Open magnetron wiring between Inverter and
magnetronterminal.
2.Between 1.0A
and2.0A.
CheckcontinuityofD702inInverterPCB.
1.D702shorted
ReplaceH.V.Inverter
(F606YM300GP)
2.D702isOK Replacemagnetron
Shutoffin3seconds
after“Start”
1. Less than
0.5A
Check open circuit: Latch Switch, DPC,
PowerRelayandCN701
Replace defective component(s), or correct
switch,cablesandconnectors.