20
5.5. Compressor Rotational Speed Control
1. When power is turned on, rotational speed is fixed 42 (r/s) for 10 minutes.
2. The use rotational speed.
Compressor rotational speed decided by the ATC temperature.
• Each ATC temperature condition, for the first step, it starts the lowest rotational speed of available range.
• If the temperature difference is big between PCC and FCC, the rotational speed changes one rank up.
5.6. Compressor Starting Control
The compressor is not start while waiting timer is operating.
And when power is turned on, compressor starting control is not available.
5.7. Compressor Fan Control (for cool down the Compressor)
Acording to the compressor rotational speed, compressor rotation speed controlled under the below.
ATC temperature Compressor rotational speed
25 r/s 33 r/s 42 r/s 52 r/s 67 r/s 75 r/s
22C below O O O O
23 ~ 28C OOOOO
29 ~ 32C OOOOO
33C above O O O O
After power turning on 0 minute
After FC Defrost stopping (Improvement of start after defrost) 10 minutes
After compressor stopping (Prevention of trip when re-starting) 10 minutes
Inverter protection 10 minutes