EasyManua.ls Logo

Panasonic PAPAMY1702034CE - Page 10

Panasonic PAPAMY1702034CE
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Item Unit OUTDOOR UNIT
Heat Exchanger
Type Plate fin configuration forced draft type
Tube Material Copper
Fin Material Aluminum (Pre Coat)
Row / Stage 2 / 28
FPI 17
Air Volume High (Cooling / Heating)
m
3
/min
(ft
3
/mm)
28.5 (1005) / 36.9 (1305)
Refrigerant Control Device Expansion Valve
Refrigerant Oil cm
3
FW50S (450)
Refrigerant (R32) g 1.12k
Dry Bulb Wet Bulb
Outdoor Operation Range
Cooling
Maximum °C 46 26
Minimum °C -10
Heating
Maximum °C 24 18
Minimum °C -15 -16
Note
Specifications are subject to change without notice for further improvement.