Chapter 5 Maintenance — Self-diagnosis display
192 - ENGLISH
Error/warning display Details Measure
F91 FPGA1/2 conguration error
f If the display does not clear after switching the
main power off and on, consult your dealer.
F92 FPGA3 conguration error
F96 Lens mounter error
FE0 Color prism fan 4 error
FE1 Exhaust fan 1 error
FE2 Exhaust fan 2 error
FE3 Exhaust fan 3 error
FE4 Exhaust fan 4 error
FE5 Intake fan 1 error
FE6 Intake fan 2 error
FE7 Lamp 1 fan error
FE8 Lamp 2 fan error
FE9 Lamp 3 fan error
FF0 Lamp 4 fan error
FF1 Lamp 1/2 power supply fan error
FF2 Lamp 3/4 power supply fan error
FF3 Power supply fan error
FF4 Signal fan error
FF5 Lamp 1/2 relay fan error
FF6 Lamp 3/4 relay fan error
FF7 Color prism fan 1 error
FF8 Color prism fan 2 error
FF9 Color prism fan 3 error
FJ0 Liquid cooling pump R error
FJ1 Liquid cooling pump G error
FJ2 Liquid cooling pump B error
*1 Refer to “Operating environment temperature” (x page 216) for the operating environment temperature of the projector.
*2 Only for PT-DZ16K2
*3 800 hours when using the optional Replacement lamp unit (for portrait mode) (Model No.: ET-LAD520P (1 pc), ET-LAD520PF (4 pcs)).
Note
f The self-diagnosis display and the details of the malfunction may vary.
f For errors and warnings that are not described in the table, consult your dealer.