Control commands via LAN (continued)
When WEB Control administrator rights password is not set (Non-protect mode)
Connection method
Obtain the IP address and port number (Initial set value = 1024) of the projector and 1)
make a request for connection to the projector.
You can obtain both IP address and port number from the menu screen of the projector.
IP address : Obtain from MAIN MENU → [NETWORK] → [NETWORK STATUS]
Port No. : Obtain from MAIN MENU → [NETWORK] → [NETWORK CONTROL] → [COMMAND PORT]
There is a response from the projector.2)
Response data
Data section Blank Mode Termination symbol
“NTCONTROL
(ASCII string)
0x20
‘0’
0x30
(CR)
0x0d
9 bytes 1 byte 1 byte 1 byte
Mode : 0 = Non-protect mode
Command transmission method
Transmit by the following command format.
Transmitted data
Header Data section Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte 1 byte Undened length 1 byte
Receive data
Header Data section Termination symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte 1 byte Undened length 1 byte
Receive data
Error message Termination symbol
ERR1
ERR2
ERR3
ERR4”
ERR5”
ERRA”
Undened control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes 1 byte