Example of the E-mail sent for an error
The following E-mail is sent when an error has occurred.
=== Panasonic projector report(ERRO R) ===
Projector T ype : PT -RZ 120
Serial No : 123456789012
----- ERROR INFORMATION -----
U21 Int ake air t emp. error
Error code
00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 00
Intake air temperat ure : 25 degC / 77 degF
O pt ics module temperat ure : 28 degC / 82 degF
Exhaust air temperat ure : 28 degC / 82 degF
Light1 t emperat ure : 28 degC / 82 degF
Light2 t emperat ure : 29 degC / 84 degF
PRO JECT O R RUNTI ME 7 H
PO WER O N 132 times
LIG HT1 RUNT I ME 7 H
LIG HT 1 ON 174 times
LIG HT2 RUNT I ME 7 H
LIG HT 2 ON 177 times
-------- Current status ---------
MAIN VERSION 1.00
SUB VERSION 1. 00
LIG HT ST AT US LI G HT1=ON LIG HT2=O N
INPUT SDI1
SIGNAL NAME ---
SIG NAL F REQ UENCY ---kHz / ---Hz
REMOTE2 STATUS DISABLE
----- Wired Network configuration -----
DHCP Client O FF
IP address 192.168. 0. 8
MAC address 12: 34: 56:78:90: 12
Mon Jan 01 12: 34: 56 20XX
----- Memo -----