Chapter 4 Settings — [PROJECTOR SETUP] menu
ENGLISH - 125
2) Press the <ENTER> button.
f The [BRIGHTNESS CONTROL] screen is displayed.
3) Press as to select [BRIGHTNESS CONTROL SETUP].
4) Press the <ENTER> button.
f The [BRIGHTNESS CONTROL SETUP] screen is displayed.
5) Press as to select [CONSTANT MODE].
6) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF] Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
When the brightness of light source or white balance changes, the brightness of the projected image
is automatically corrected.
[PC]
Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring
& Control Software”
*1
.
*1 “Multi Monitoring & Control Software” is included in the supplied CD-ROM.
f Proceed to Step 9) when [PC] is selected.
7) Press as to select [LINK].
8) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
Performs correction by the brightness sensor on one projector without synchronizing with the other
projectors.
The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
OUTPUT] smaller.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Performs correction by the brightness sensor in multiple projectors in synchronization.
Up to four groups (A to D) can be set within the same subnet by using the network function.
Up to eight projectors can be registered and synchronized in one group.
9) Press as to select [CALIBRATION TIME].
10) Press the <ENTER> button.
f The projector is in the adjustment mode (the time is blinking).
11) Press qw to select “hour” or “minute”, and press as or the number (<0> - <9>) buttons to set a
time.
f Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows
setting of only the minute in increments of one minute between 00 and 59.
f When the time is not specied, select [OFF] between 23 and 00 of the hour, or between 59 and 00 of the
minute.
12) Press the <ENTER> button.
f [CALIBRATION TIME] is set.
f Brightness and color are measured at the specied time. The dynamic contrast function does not operate
during measurement.
13) Press as to select [CALIBRATION MESSAGE].
14) Press qw to switch the item.
f The items will switch each time you press the button.
[ON] Displays messages during calibration.
[OFF] Does not display messages during calibration.
15) Press as to select [APPLY].