TC-L32X30
13
6.2. Power LED Blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality occurs, the protection circuit will operate and reset the unit to stand by mode. During this time, the
defective block can be identified by the number of blinking times of the Power LED on the front panel of the unit as follow:
6.3. No Power
First check point
There are following 2 states of No Power indication by power LED.
1. No lit
2. Red is lit then turns red blinking a few seconds later. (See 6.2.)
LCD
Remark
EEPROM ADR
address
PCB NAME
Times SOS
1 BackLight_SOS 0×0461 TNPH0906/0907
2 FAN_SOS Peaks 0×045C
3 SOS(Tuner_SOS) SUB3.3V/panel_15V 0×045B
4 SUB12V_SENSE_SOS 0×045A
7 SUB3.3V_SENSE_SOS 0×0459
9 SOUND_SOS 0×045D
10 ZWEI2_SOS detect of IIC 0×0462
12 BackEnd(sLD)_SOS 0×0466
13 EMERGENCY_SOS communication error
14 IROM_SOS Error of STM micon