TC-L42E5X
30
8 Measurements and Adjustments
8.1. Voltage chart of A-board
Set A-Board to a dummy set and check the satisfaction with the specified voltage as following table.
8.2. Voltage chart of P-board
Set P-Board to a dummy set and check the satisfaction with the specified voltage as following table.
VOLTAGE TEST POINT SPECIFICATION
PANEL12V TP4004/TP4005 11.45V - 12.55V
USB_5V TP5440 4.80V - 5.25V
SUB5V TP5420 4.95V - 5.65V
SUB3.3V TP5400 3.17V - 3.43V
SUB1.8V TP8700 1.7V - 1.9V
SUB1.5V TP8101 1.435V - 1.585V
SUB1.1V TP8100 1.10V - 1.22V
VOLTAGE TEST POINT
SPECIFICATION
OPERATE FUNCTION STANDBY
5VS TP7412, 7507 5.3 V ± 0.1 V
16V TP7508, 7514 16.1 ± 0.6 V
24V TP7512, 7513 24 V ± 1.2 V