8 Alignment
Preparation:
1. Connect the Digital media receiver to the Plasma display by the system cables.
2. Place the units into IIC mode of CAT mode.
8.1. Sub contrast adjustment (NTSC)
Preparation
PICTURE:VIVID (NORMAL SET)
ADJUSTMENT DATA: BRIGH, CONT
Note:
Set ABL operation to off in Contrast adjustment.
Measurement Instrument Remarks
1. Oscilloscope
2. Alignment equipment
Extension cable kit (Part No.TZSC0704)
3. Remote control
Picture menu: VIVID
Picture pattern: Studio color bar
Probe: The signal should be terminated by 75W, ±1% resistor.
Not use Cross hatch signal
Adjustment Procedures
1. Apply the 10 stair-step (B/W) signal to Composite video input.
2. Connect the Oscilloscope to CN3303-A38 (G out) of G-Board.
3. Adjust Sub contrast so that the B-W (Blanking portion-White) is 0.60V±0.02V.
4. Also connect the oscilloscope to CN3303-A34 (R out) and observe both waveforms simultaneously.
5. Adjust R-drive so that the amplitude of R signal is same as G signal.
6. Connect the Oscilloscope to CN3303-A36 (B out) and CN3303-A38 (G out), and observe the both waveforms simultaneously.
7. Adjust B-drive so that the amplitude of B signal is same as G signal.
13