Europe
PRECAUTION OF LOW TEMPERATURE
In order to avoid frostbite, be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit.
WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to
service or repair the products dealt with in this service information by anyone else could result in serious injury or death.

Table of Contents

Questions and Answers

  • A
    Amy KellerSep 15, 2025
    What does Outdoor Air Temperature Sensor Abnormality (F36) mean for my Panasonic WH-SHF09F3E5 Heat Pump?
    • D
      David JohnsonSep 15, 2025
      An Outdoor Air Temperature Sensor Abnormality (F36) in your Panasonic Heat Pump can be caused by: * Faulty connector connection. * Faulty sensor. * Faulty outdoor unit PCB (main). Continue for 5 seconds.
  • C
    Christina MercadoAug 25, 2025
    What causes a Compressor Low Pressure Protection (H42) error in my Panasonic WH-SHF09F3E5 Heat Pump?
    • M
      Maria CollierAug 25, 2025
      A Compressor Low Pressure Protection (H42) error in your Panasonic Heat Pump can be triggered by: * Dust accumulation on the outdoor unit heat exchanger. * Air short circuit at the outdoor unit. * A partially closed 3-way valve. * A faulty outdoor unit fan motor. * Refrigerant shortage (refrigerant leakage). * A clogged expansion valve or strainer. * A faulty outdoor pipe temperature sensor. * A faulty outdoor unit main PCB (main).
  • D
    Donald MillerAug 25, 2025
    What does Outdoor High Pressure Abnormality (H64) mean for my Panasonic Heat Pump?
    • L
      lisa60Aug 26, 2025
      If your Panasonic Heat Pump displays an Outdoor High Pressure Abnormality (H64), it could be due to: * A faulty connector connection. * A faulty sensor. * A faulty outdoor unit PCB (main). In this case, continue 4 times in 20 minutes.
  • J
    Jennifer HansenAug 27, 2025
    Why does my Panasonic WH-SHF09F3E5 Heat Pump display Indoor/Outdoor Abnormal Communication (H90)?
    • C
      Carol JacksonAug 27, 2025
      The Panasonic Heat Pump may display an Indoor/Outdoor Abnormal Communication (H90) error if there is: * A faulty outdoor unit PCB (main). * A faulty indoor unit PCB (main). * An indoor-outdoor signal transmission error due to wrong wiring. * An indoor-outdoor signal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units. * An indoor-outdoor signal transmission error due to disturbed power supply waveform. Continue for 1 minute after operation.
  • S
    Steven BrownSep 16, 2025
    What does Indoor Water Inlet Temperature Sensor Abnormality (F37) mean on my Panasonic WH-SHF09F3E5 Heat Pump?
    • H
      Heather BaileySep 16, 2025
      An Indoor Water Inlet Temperature Sensor Abnormality (F37) in your Panasonic Heat Pump could be due to: * Faulty connector connection. * Faulty sensor. * Faulty indoor unit PCB (main). Continue for 5 seconds.
  • B
    Brian MartinSep 23, 2025
    What does Outdoor Current Transformer Open Circuit (F46) mean for my Panasonic Heat Pump?
    • D
      Dawn ParkerSep 23, 2025
      An Outdoor Current Transformer Open Circuit (F46) in your Panasonic Heat Pump may indicate: * CT defective. * Faulty outdoor unit PCB. * Compressor defective (low compression). Continue 3 times in 20 seconds.
  • A
    Alicia BrockSep 8, 2025
    What does Deice Circulation Error (H65) mean on my Panasonic WH-SHF09F3E5?
    • J
      Jessica GrimesSep 8, 2025
      A Deice Circulation Error (H65) on your Panasonic Heat Pump could indicate: * Water flow in air-to-water heatpump indoor unit circuitry. * Faulty indoor unit water flow switch. * Faulty indoor unit water pump. * Faulty indoor unit PCB. Continue for 10 seconds.
  • C
    Christine BowmanSep 9, 2025
    What does Water Pump Abnormality (H20) mean for my Panasonic WH-SHF09F3E5 Heat Pump?
    • E
      Elizabeth RuizSep 9, 2025
      A Water Pump Abnormality (H20) in your Panasonic Heat Pump may be due to: * Operation stop due to short circuit inside the water pump motor winding. * Operation stop due to breaking of wire inside the water pump motor. * Operation stop due to breaking of water pump lead wires. * Operation stop due to water pump motor IPM malfunction. * Operation error due to faulty indoor unit PCB. Continue for 5 seconds.
  • A
    Alex HayesSep 2, 2025
    What does Outdoor High Pressure Switch Activate (F12) mean for my Panasonic WH-SHF09F3E5?
    • M
      Mike AndrewsSep 2, 2025
      If your Panasonic Heat Pump displays Outdoor High Pressure Switch Activate (F12), it could be caused by: * Faulty water pump. * Insufficient water flow rate in system. * Water leak in system. * 3 way valve closed. * Clogged expansion valve or strainer. * Excessive refrigerant. * Faulty outdoor high pressure sensor and switch. * Faulty outdoor unit PCB. Continue 4 times in 20 minutes.
  • W
    walkerrogerAug 31, 2025
    What causes a Four Way Valve Abnormality (F25) in my Panasonic WH-SHF09F3E5 Heat Pump?
    • J
      jeanettehawkinsSep 1, 2025
      A Four Way Valve Abnormality (F25) in your Panasonic Heat Pump can be caused by: * A faulty sensor. * A faulty connector connection. * A faulty outdoor unit PCB (noise filter/main). * A faulty four-way valve. Continue 4 times in 30 minutes.

Summary

Safety Precautions

Specifications

Model Specifications (WH-SHF09 F3 E5;WH-UH09 FE5)

Detailed specifications for the WH-SHF09F3E5 and WH-UH09FE5 models.

Model Specifications (WH-SHF12 F6 E5;WH-UH12 FE5)

Detailed specifications for the WH-SHF12F6E5 and WH-UH12FE5 models.

Features

Controls and Components Location

Indoor Unit Controls Overview

Identifies indoor unit controls and panel layout.

Adjusting Initial Settings and Usage

Guides on initial settings and basic operation functions.

Dimensions

Indoor Unit Dimensions

Provides dimensional drawings and measurements for the indoor unit.

Outdoor Unit Dimensions

Provides dimensional drawings and measurements for the outdoor unit.

Refrigeration and Water Cycle Diagram

Block Diagram

Wiring and Circuit Diagrams

Indoor Unit Wiring & Circuits

Wiring and electronic circuit diagrams for the indoor unit.

Outdoor Unit Wiring & Circuits

Wiring and electronic circuit diagrams for the outdoor unit.

Printed Circuit Board Layouts

Indoor Unit PCBs

Main and optional solar PCB layouts for the indoor unit.

Outdoor Unit PCBs

Main PCB layout for the outdoor unit.

Installation Instructions

Location Selection and Unit Mounting

Guidelines for selecting location and mounting indoor/outdoor units.

Piping and Drain Hose Installation

Procedures for installing refrigerant and water piping, and drain hose.

Electrical Cable Connections

Procedures for connecting electrical cables to both units.

System Evacuation and Pipe Prep

Procedures for refrigerant system evacuation and pipe cutting/flaring.

Operation and Control

Basic Operation Modes

Explains heating, tank, and heat+tank modes.

Water Pump and Safety Controls

Explains water pump control, safety features, and indicators.

Specialized Operation Modes

Details sterilization, quiet, anti-freeze, solar, and thermostat controls.

Protection Control

General Operation Protection

Covers time delay, current, and compressor overheating protection.

Heating Operation Protection

Details protection controls specific to heating, including deice operation.

Servicing Guide

Component Removal Procedures

Steps for removing front plate, side cabinet, and pump down.

Service Mode Operations

How to adjust flow rate, dry concrete, and perform EEPROM setup.

Maintenance Guide

Regular Unit Checks

Covers water pressure, relief valve, air purge, and control board checks.

Component Maintenance Procedures

Procedures for resetting overload protector and cleaning external filter.

Troubleshooting Guide

Refrigeration Cycle & System Conditions

Diagnosing issues within the refrigeration cycle and relating conditions to pressure/current.

Breakdown Self Diagnosis & Error Codes

How to access, interpret error codes, and perform self-diagnosis.

Specific Malfunction Troubleshooting

Detailed troubleshooting steps for various component errors (e.g., sensors, pumps, valves).

Disassembly and Assembly

Internal Component Removal

Steps for removing control panel, RCCB, transformer, and electronic board.

Valve, Pump & Bottle Removal

Steps for removing pressure relief valve, flow switch, air purge valve, water pump, and bottle.

Technical Data

Operation Characteristics

Graphs showing capacity and input power vs. temperature/piping length.

Heating Capacity Tables

Tables detailing heating capacity and input power.

Usage Limitations

Defines the operational limits of the unit.

Exploded Views & Parts List

Parts List (WH-SHF Series)

Exploded view and parts list for WH-SHF09F3E5/WH-SHF12F6E5.

Parts List (WH-UH Series)

Exploded view for WH-UH09FE5/WH-UH12FE5 units.