Menu Default Setting Setting Options / Display
Outdoor temp. for heating OFF
24 °C
Temperature for
heating OFF
T for heating ON
5 °C
Set
T for heating
ON.
* This setting will not
available to set when
pump owrate set to
Max. duty.
Heater ON/OFF
Heater ON/OFF Outdoor temp. for heater ON
0 °C
Temperature for
heater ON
Heater ON/OFF Delay time for heater ON
0:30 min
Delay time for heater
to turn on
Heater ON/OFF Water temperature for heater ON
-4 °C
Setting of water
temperature to turn
on from water set
temperature.
Heater ON/OFF Water temperature for heater OFF
-2 °C
Setting of water
temperature to turn
off from water set
temperature.
6.2
*
1,
*
2
Cool
To set various water & ambient
temperatures for cooling.
Water temperatures for cooling ON
and
T for cooling ON.
*
1
The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.
*
2
Only displayed when COOL mode is unlocked (This means when COOL mode is available).