26 Reference & Installation Manual
Options [4] to [6] represent the alarm types of panic alarms 1 to 3
respectively.
Silent Alarm: The Magellan console will emit a confirmation beep
and transmit the appropriate Panic report code (if programmed in
section [139]). The console will not enable its speaker or the
system siren.
Audible Alarm: Same as the silent alarm except that the console
will enable its speaker and system siren until a user cancels the
alarm (disarms) with a valid Access code or when the Bell Cut-off
timer elapses (if enabled; see Bell Cut-off Timer on page 24).
Pulsed Alarm (Fire Panic only): Same as the audible alarm
except that the siren will be pulsed as shown in Figure 18 on
page 15. Refer to Standard 24Hr. Fire Zones on page 15 for
more information on a pulsed siren output.
Remote Panic Disarm Lock Delay
Section [078]: 001 to 255 seconds; 000 = Disabled; Default = 20
seconds
When a panic alarm is generated through the use of a remote
control, the system cannot be disarmed by remote control during
the Remote Panic Disarm Lock Delay.
Enter the desired 3-digit delay value into section [078] to
program the Remote Panic Disarm Lock Delay.