28  Reference & Installation Manual
• Fire Panic: Panic keys [7] and [9] (see page 25) or the 
appropriate button(s) on a remote control (see page 19) 
have been pressed.
• Recent Closing: Reports when an alarm is generated after 
arming the system within the period defined by the Recent 
Close Delay (see page 32).
Section [140]
• Auto-zone Shutdown: A zone communicates more than the 
programmed number of transmissions in a single armed 
period (see page 16). 
• Duress: A Duress code is keyed in (see page 13). 
• Paramedical alarm
Zone Tamper Report Codes
Section [141] to [144]
A report code can be programmed for each of the 16 available 
zones. Whenever a tamper or wire fault occurs on a zone, the 
Magellan console can send the appropriate report code to the 
monitoring station identifying which zone was tampered.
If Tamper Recognition (see page 24) is disabled, the 
console will not report the occurrence of any tampers, 
wire faults or tamper restores.
Zone Tamper Restore Report Codes
Sections [145] to [148]
A report code can be programmed for each of the 16 available 
zones. Whenever a tampered zone is restored, the Magellan 
console can send the appropriate report code to the monitoring 
station identifying which zone has been restored.
If Tamper Recognition (see page 24) is disabled, the console 
will not report the occurrence of any tampers, wire faults or 
tamper restores.
System Trouble Report Codes
Section [149] to [151]
Whenever the system generates one of the instances listed 
below, the console can send the appropriate report code to the 
monitoring station identifying the type of system trouble.
Section [149]
• Console Tamper: A tamper has been detected on the 
console itself (see Console Tamper Supervision on page 
35).
• AC Failure: Magellan has detected a loss of AC power. 
Transmission of this report code can be delayed (see Power 
Failure Report Delay on page 32).
• Battery Failure: The backup battery is disconnected or 
battery voltage is ≤ (less than or equal to) a certain voltage.
• Timer Loss: The console has detected a loss in time or clock 
failure.
Section [150]
• Fail To Communicate: The Magellan console has failed all 
attempts to communicate with the monitoring station. The 
report code will be transmitted upon the next successful 
attempt.
• Wireless Low Battery: The battery voltage of an Omnia 
wireless transmitter (motion detector or contact switch) has 
dropped below recommended limits.
• Tx Supervision Loss: Check-in Supervision (see page 24) 
has been enabled and a transmitter is no longer 
communicating with the system.
Section [151]
• RF Interference: The Magellan console has encountered RF 
Interference (see RF Interference Detection on page 32).
• PGM Supervision Loss: Wireless PGM Supervision (see 
Wireless PGM Supervision Options on page 25) has been 
enabled and a MG-2WPGM is no longer communicating 
with the system.
• PGM Tamper: A tamper has been detected on a MG-
2WPGM.
System Trouble Restore Codes
Sections [152] to [154]
Whenever the system restores one of the troubles listed in 
sections [149] to [151] (see System Trouble Report Codes on 
page 28), the Magellan console can send the appropriate report 
code to the monitoring station identifying the type of system 
trouble restored. If Telephone Line Monitoring is enabled (see 
page 31), use the first two digits to program a TLM Restore 
report code that the console can transmit.
Special Reporting Codes
Sections [155] and [156]
Whenever the system generates one of the instances listed 
below, the Magellan console can send the appropriate report 
code to the monitoring station identifying the type of system 
occurrence.
Section [155]
• Cold Start: The console was completely shut down (no 
battery, no AC) and then was restarted.
• Test Report: A test report has been generated automatically 
(see page 32).
• WinLoad Logout: The console has ended communication 
with WinLoad.
Section [156]
• Installer logon: Installer has entered the programming 
mode.
• Installer Logout: Installer has exited the programming mode.
• Closing Delinquency: The last time the system was armed is 
greater than the programmed Closing Delinquency timer 
(see page 23).
Console Telephone Numbers
Magellan can dial up to two different monitoring station 
telephone numbers and one Pager telephone number. You can 
enter any digit from 0 to 9 and any special keys or functions (see 
Table 9 on page 29) up to a maximum of 32 digits. If the number 
is less than 32 digits, press the left [
ACTION
] key (
OK
) to save the 
message.