EN Certification
The following statements apply for EN 50131 and EN 50136 certification:
• Mode of operation is pass-through.
• PCS265V8 must be installed and connected to an EN approved Grade 3 control panel.
• Monitoring of the transmission network interface (Internet connection): In case of network/interface failure, the device sends
a trouble message to the control panel which then displays it via connected keypad(s).
• Information Security is achieved by 256-bit encrypted, supervised communication (AES validation number 986) which prevents
unauthorized reading or modification of messages.
• Substitution Security is achieved by Information Security (as stated above), physical security (Tamper protection) and by a unique Serial
Number from each device. Messages sent to the receiving station include the S/N to identify the substitution and alert accordingly.
Technical Specifications
Class 4 (2W) @ 850/1900 MHz
Class 2 (1W) @ 1800/1900 MHz
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)
Consumption during
LTE transmission
60 mA standby
300 mA maximum
7-bit (GSM: 3GPP TS 23.038/GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)
-20 - 50 °C (-4 to 122 °F)
20.8 x 7.5 x 2 cm / 8.2 x 2.9 x 0.8 in.
EN 50136-1 EN 50136-2 Grade 3
Class II EN 50131-10 ATS Category SP5 Certification Body:
Applica Test and Certification
Safety Note: This device may operate continuously in temperatures of 55°C (131°F) for a maximum period of 7 days.
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site www.paradox.com/Terms. or contact your local
distributor. Specifications may change without prior notice.
Patents
US, Canadian and international patents may apply. Paradox is a trademark or registered trademarks of Paradox Security Systems (Bahamas) Ltd. © 2024 Paradox Security
Systems (Bahamas) Ltd. All rights reserved. www.paradox.com