EasyManuals Logo

Paradox SP5500 Installation Guide

Paradox SP5500
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Magellan & Spectra SP • Installation Guide
27
Partition 2 Assignment
Sections [404] to [432]: User Codes 004 to 032
Option [2] OFF= Deny access to partition 2 (default)
Option [2] ON= User code has access to partition 2
If the system is partitioned (See “Partitioning” on page 58), user codes with this option enabled can arm and disarm partition 2. If the system is not partitioned, the
control panel ignores this option.
Bypass Programming
Sections [404] to [432]: User Codes 004 to 032
Option [3] OFF= Bypass Programming Disabled
Option [3] ON= Bypass Programming Enabled (default)
User codes with this option enabled can perform Bypass Programming in assigned partitions.
Stay/Sleep Arming
Sections [404] to [432]: User Codes 004 to 032
Option [4] OFF= Stay/Sleep Arming Disabled
Option [4] ON= Stay/Sleep Arming Enabled for selected User Code (default)
User codes with this option enabled can Stay or Sleep arm assigned partitions.
Force Arming
Sections [404] to [432]: User Codes 004 to 032
Option [5] OFF= Force Arming Disabled
Option [5] ON= Force Arming Enabled for selected User Code (default)
User codes with this option enabled can Force arm assigned partitions.
Arm Only
Sections [404] to [432]: User Codes 004 to 032
Option [6] OFF= Arm Only Disabled (default)
Option [6] ON= Arm Only Enabled for selected User Code
The user code with this option enabled can arm assigned partitions, but cannot disarm any partitions. The type of arming is dependent on the other User Code
Options selected. Please note that with the Arm Only option, the user can cancel a recently armed system by re-entering the access code before the end of the exit
delay.
PGM Activation
Sections [404] to [432]: User Codes 004 to 048
Option [7] OFF= User Code follows User Code Options and can activate a PGM (default)
Option [7] ON= User Code can activate a PGM only
With option [7] off, entering the access code will arm or disarm according to the programmed User Code Options as well as activate or deactivate a PGM. The
appropriate PGM Activation/Deactivation Event must also be programmed (See “Programmable Outputs” on page 56). With option [7] on, the control panel will
ignore all other User Code Options. Therefore, entering the access code will only activate or deactivate the PGM.
Duress
Sections [404] to [432]: User Codes 004 to 032
Option [8] OFF= User Code with duress disabled (default)
Option [8] ON= User Code with duress enabled
If you are coerced into arming or disarming your system, entering the access code with the duress option enabled will arm or disarm the system and immediately
transmit a silent alert (Duress Code) to the monitoring station.
Lock Master Code
Section [701]: System Options
Option [2] OFF= Lock System Master Code Disabled (default)
Option [2] ON= Lock System Master Code Enabled
With this feature enabled, the control panel will lock the System Master Code (001), it cannot be modified. With this feature disabled, the control panel will unlock
the System Master Code, so that it can be changed. The System Master Code cannot be deleted (see Master Quick Menu Programming in the User Guide).

Table of Contents

Other manuals for Paradox SP5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP5500 and is the answer not in the manual?

Paradox SP5500 Specifications

General IconGeneral
BrandParadox
ModelSP5500
CategorySecurity System
LanguageEnglish

Related product manuals