Magellan & Spectra SP • Installation Guide
Tamper Supervision on Panel (MG5075 only)
Section [700]: Supervision Options
Option [8] OFF= Panel tamper supervision disabled
Option [8] ON= Panel tamper supervision enabled (default)
When the control panel detects a tamper, the control panel can generate an alarm or trouble, unless the Tamper Supervision is disabled.
Keypad Panic Options
Section [702]: General Options
Option [1] OFF= Panic 1 Disabled (default)
Option [1] ON = Panic 1 Enabled
Pressing the [1] and [3] keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option [4].
Option [2] OFF= Panic 2 Disabled (default)
Option [2] ON = Panic 2 Enabled
Pressing the [4] and [6] keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option [5].
Option [3] OFF= Panic 3 Disabled (default)
Option [3] ON = Panic 3 Enabled
Pressing the [7] and [9] keys simultaneously on the keypad for 3 seconds will generate a silent or audible alarm as defined by option [6].
Option [4] OFF= Panic 1 is Silent (default)
Option [4] ON = Panic 1 is Audible
Option [5] OFF= Panic 2 is Silent (default)
Option [5] ON = Panic 2 is Audible
Option [6] OFF= Panic 3 is Silent (default)
Option [6] ON = Panic 3 is Audible
Silent alarm:
The control panel emits a confirmation beep and transmits the appropriate Panic report code if programmed in section [863]. The control panel will not enable the
keypad buzzers or the control panel’s
BELL output (no audible alarm).
Audible alarm:
Same as silent alarm, except the keypad buzzers and the BELL output will activate until a user cancels the alarm (disarms) with a valid user access code or when the
Bell Cut-Off Timer elapses (See “Bell Cut-Off Timer” on page 47).
Whether the system is partitioned or not, the control panel will report all panic alarms to partition 1.
Panic Lockout Timer
Section [718]
When a panic alarm is activated, the control panel can ignore the disarm signal from a remote control for a specified period. This prevents an aggressor from
disarming the system by remote control during a panic situation. In section [718] enter a 3-digit value (000 to 255, 000 = disabled) representing the number of
seconds that the remote controls will be locked out of the system.
Flex-Instant Delay
Section [720]
The Flex-Instant Delay is used to prevent false alarms when the premises is Stay/Sleep armed. In section [720] enter a 3-digit value (000 to 255, 000 = disabled)
representing the number of seconds that the panel will delay an alarm allowing you to disarm the system (default 15 seconds).

Table of Contents

Other manuals for Paradox SP7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP7000 and is the answer not in the manual?

Paradox SP7000 Specifications

General IconGeneral
Partitions2
Event Buffer256 events
Wireless Zones32
PGM Outputs2
CompatibilityParadox modules and accessories
CommunicationGSM, IP
System TypeHybrid
Power Supply16.5VAC
Backup Battery7Ah
Bus4-wire (Digiplex EVO)

Related product manuals