Magellan & Spectra SP • Installation Guide
53
If the Alternate Dial option is enabled, the control panel will dial the programmed backup telephone number (if enabled) after every failed attempt. If no backup
telephone number is programmed, the control panel will never report to the backup telephone number.
Example: The system is armed and zone 1 has been breached causing an alarm. If options [5] and [7] are OFF and option [6] is ON in section [802], the control panel
will attempt to communicate with MSTN 2.
Account Numbers
Section [811]: Partition 1, Section [812]: Partition 2
All report codes are preceded by a 4-digit or 3-digit Partition Account Number to ensure correct identification in a partitioned system. Partition account numbers
can be any hexa-digit from 1 to F. To enter a 3-digit account number, simply press the [
SLEEP] key followed by a 3-digit account number. Also, when using 3-digit
account numbers, you must use 1-digit report codes.
Dialing Method
Section [800]: Dialer Options
Option [6] OFF= Pulse Dialing (See “Pulse Ratio” on page 53).
Option [6] ON= Tone/DTMF Dialing (default)
Pulse Ratio
Section [800]: Dialer Options
Option [7] OFF= European Pulse Ratio of 1:2
Option [7] ON= U.S.A. Pulse Ratio of 1:1.5 (default)
When using Pulse dialing, you can select one of two Pulse Ratios. Although most European countries use the 1:2 pulse ratio, the 1:1.5 ratio may provide better results
in some cases. The same applies for North American countries. If the 1:1.5 pulse ratio is not providing the desired results, the 1:2 ratio may be used.
Maximum Dialing Attempts
Section [831]
000 to 255 attempts, Default = 8 attempts
The value programmed in section [081] determines how many times the control panel will re-dial the same monitoring station telephone number before
proceeding to the next number.
Maximum Dialing Attempts - VDMP3
Section [841]
000 to 255 attempts, Default = 8 attempts
The value programmed in section [841] determines how many times the control panel will re-dial the same telephone number before proceeding to the next
number. The maximum dialing attempts programmed in this section is independent from those programmed in section [831] of the panel dialer used for
monitoring station reporting.
Delay Between Dialing Attempts
Section [832]
000 to 255 seconds, Default = 20 seconds
This delay determines the amount of time the control panel will wait between each dialing attempt. This section applies to the Plug-in Voice Dialer when using
a VDMP3.
Switch to Pulse on 5th Attempt
Section [800]
Option [3] OFF= Switch to Pulse on 5th Attempt Disabled (default)
Option [3] ON= Switch to Pulse on 5th Attempt Enabled
With option [3] ON, the control panel will switch to pulse dialing on the 5th attempt of reaching the monitoring station.
Alternate Dial Option
Section [800]: Dialer Options
Option [4] OFF= Alternate Dial Disabled (default)
Option [4] ON= Alternate Dial Enabled
With option [4] OFF, the control panel will dial the backup programmed in section [817] after all attempts to one monitoring station number have failed. With
option [4] ON, the control panel will dial the backup number after every failed attempt.
Force Dial Option
Section [800]: Dialer Options
Option [5] OFF= Force Dial Disabled
Option [5] ON= Force Dial Enabled (default)
With option [5] is enabled, the panel will dial a telephone number even if no dial tone is present after 4 seconds.

Table of Contents

Other manuals for Paradox SP7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP7000 and is the answer not in the manual?

Paradox SP7000 Specifications

General IconGeneral
Partitions2
Event Buffer256 events
Wireless Zones32
PGM Outputs2
CompatibilityParadox modules and accessories
CommunicationGSM, IP
System TypeHybrid
Power Supply16.5VAC
Backup Battery7Ah
Bus4-wire (Digiplex EVO)

Related product manuals