48 Reference & Installation Manual
If Hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports
Hexadecimals. If the pager does not support Hexadecimals, use only the digits 0 to 9.
UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least
once per year.
12.13.1 Standard Pulse Formats
The control panel can use the Ademco slow, Silent Knight and Sescoa standard pulse reporting formats which will
transmit the 2-digit (00 to FF) report codes programmed into sections [860] to [876]. (see Table 6 on page 48).
12.13.2 Ademco Express
The Ademco Express is a high-speed reporting format, which will transmit the 2-digit (00 to FF) report codes programmed
into sections [860] to [876].
12.13.3 Ademco Contact ID
Ademco Contact ID is a fast communicator format that uses tone reporting instead of pulse reporting. This communicator
format also uses a pre-defined list of industry standard messages and report codes that will suit most of your basic
installation needs. Please refer to the Contact ID Report Codes List in the Programming Guide for a complete list of these
report codes and messages. If the reporting codes are set at 0xFF, the panel will send the appropriate report code from
the Automatic Report Code List in the programming guide. Alternatively, report codes can be programmed using the
Ademco Contact ID Report Codes in the programming guide.
12.13.4 Event Call Direction
Section [802]: Options [1] to [3]; Arming/Disarming
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [802]: Options [5] to [7]; Alarm/Alarm Restore
Option [5] ON =Call MSTN 1
Option [6] ON =Call MSTN 2
Option [7] ON =Call Pager telephone number
Section [803]: Options [1] to [3]; Tamper/Tamper Restore
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [803]: Options [5] to [7]; Trouble/Trouble Restore
Option [5] ON =Call MSTN 1
Option [6] ON =Call MSTN 2
Option [7] ON =Call Pager telephone number
Section [804]: Options [1] to [3]; Special Reporting
Option [1] ON =Call MSTN 1
Option [2] ON =Call MSTN 2
Option [3] ON =Call Pager telephone number
Section [804]: Options [5] to [7]; Special Reporting
Option [1] ON =Call voice on zone alarm (burglary/fire)
Option [2] ON =Call voice on panic alarms
Option [3] ON =Call voice on paramedic alarm
The events are divided into six groups (see above) where each event group can be programmed to dial up to three
telephone numbers (MSTN 1 & 2 and the Pager telephone number).
Table 6: Reporting Formats
Value Entered Reporting Format
0 Ademco Slow (1400Hz, 1900Hz, 10BPS)
1 Silent Knight Fast (1400Hz, 1900Hz, 10BPS)
2 SESCOA (2300Hz, 1800Hz, 20BPS)
3 Ademco Express (DTMF 4+2)
4 Ademco Contact ID
5SIA

Table of Contents

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah