52 Reference & Installation Manual
12.31 Personal Reporting Delay
Section [836]: Communication Timers
000 to 255 times, Max. 127, Default = 5
When using the Personal Reporting Format, the control panel will wait for the Personal Delay period before transmitting the
report codes. This is to allow time for the system to provide a dial tone or to bypass the “welcome” message before sending data.
This section applies to the Plug-in Voice Dialer when using a VDMP3.
12.32 Personal Reporting Message Repetition
Section [837]: Communication Timers
000 to 255 times, Max. 10, Default = 3
When using the Personal Reporting Format, the control panel will repeatedly send the report codes to the pager until the
transmission has been acknowledged. This section applies to the Plug-in Voice Dialer when using a VDMP3.
12.33 Disable Reporting
Sections [800]
Option [1] OFF = Dialer Activated (default)
Option [1] ON = No Dialer
With this option disabled (default), the control panel will continue to report events. With the option enabled, reporting is disabled.