AC10 series
IP20 0-180kW
HA502320U001 Issue 6
Product Manual
aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
ENGINEERING YOUR SUCCESS.

Table of Contents

Questions and Answers

  • N
    Nancy HallSep 23, 2025
    What if I entered the wrong password on my Parker 10G-11-0015 Controller?
    • T
      travisperkinsSep 23, 2025
      If you entered the wrong password on your Parker Controller when the password function is valid, set the password correctly.
  • J
    jonathon64Aug 23, 2025
    What to do if my Parker 10G-11-0015 displays 'Inverter Overload'?
    • G
      Gwendolyn MunozAug 23, 2025
      If your Parker Controller is showing an inverter overload, it could be due to a load that is too heavy. Try to reduce the load, check the drive ratio, or increase the inverter’s capacity.
  • E
    Emily TaylorAug 25, 2025
    What causes a Parker Controller to display 'Motor Overload'?
    • L
      Logan RileyAug 25, 2025
      A 'Motor Overload' message on your Parker Controller typically indicates that the load is too heavy. You should reduce the load, check the drive ratio, or increase the motor’s capacity.
  • R
    robert36Aug 27, 2025
    What should I do if my Parker 10G-11-0015 Controller shows DC Over-Voltage?
    • A
      Allison JohnsonAug 27, 2025
      If your Parker Controller displays a DC Over-Voltage error, consider the following potential causes and solutions: 1. Supply voltage too high: Check if the rated voltage is input. 2. Load inertia too big: Add braking resistance (optional). 3. Deceleration time too short: Increase deceleration time. 4. Motor inertia rise again: Set the parameter of rotary speed loop PID correctly. 5. Parameter of speed loop PID is set abnormally: Set the parameter of rotary speed loop PID correctly.
  • M
    Megan CunninghamAug 27, 2025
    What to do if Parker Controller shows Current Zero Excursion Malfunction?
    • W
      William AlvarezAug 28, 2025
      If your Parker Controller shows a 'Current Zero Excursion Malfunction', check the flat cable. If the issue persists, contact Parker.
  • C
    Catherine ChenSep 18, 2025
    How to fix communication timeout on Parker Controller?
    • L
      lbeltranSep 18, 2025
      To fix a communication timeout on your Parker Controller, check whether the communication line is connected reliably.
  • E
    Emily LittleSep 15, 2025
    What causes the wrong direction of motor running on a Parker Controller?
    • J
      jeffrey82Sep 15, 2025
      If the motor is running in the wrong direction with your Parker Controller, check if the U, V, W wiring is correct and ensure the parameters are set correctly.
  • G
    georgesimpsonSep 16, 2025
    What does 'Line Disconnected' mean on my Parker 10G-11-0015?
    • K
      Keith ChaneySep 16, 2025
      If your Parker Controller displays 'Line Disconnected', it indicates that the analog signal line is disconnected or the signal source is broken. Try changing the signal line or the signal source.
  • D
    David TapiaSep 6, 2025
    What causes a Parker Controller to have output phase loss?
    • S
      Samuel MaxwellSep 7, 2025
      An output phase loss in your Parker Controller could be due to a broken motor, loose motor wires, or a broken inverter. Check if the motor is broken, if the motor wires are loose, and if the inverter is broken.
  • M
    Mr. Samuel BakerSep 4, 2025
    What to do if my Parker Controller trips the power?
    • J
      Jon MooreSep 4, 2025
      If your Parker Controller is tripping the power, it might be because the wiring current is too high. Check the input wiring, select a matching air switch, reduce the load, and check for any inverter malfunctions.

Parker 10G-11-0015 Specifications

General IconGeneral
BrandParker
Model10G-11-0015
CategoryController
LanguageEnglish