What if I entered the wrong password on my Parker Controller?
- BbateslisaSep 23, 2025
If you entered the wrong password on your Parker Controller when the password function is valid, set the password correctly.
What if I entered the wrong password on my Parker Controller?
If you entered the wrong password on your Parker Controller when the password function is valid, set the password correctly.
What to do if my Parker Controller displays 'Inverter Overload'?
If your Parker Controller is showing an inverter overload, it could be due to a load that is too heavy. Try to reduce the load, check the drive ratio, or increase the inverter’s capacity.
What causes a Parker Controller to display 'Motor Overload'?
A 'Motor Overload' message on your Parker Controller typically indicates that the load is too heavy. You should reduce the load, check the drive ratio, or increase the motor’s capacity.
What should I do if my Parker 10G-46-0600-BF shows DC Over-Voltage?
If your Parker Controller displays a DC Over-Voltage error, consider the following potential causes and solutions: 1. Supply voltage too high: Check if the rated voltage is input. 2. Load inertia too big: Add braking resistance (optional). 3. Deceleration time too short: Increase deceleration time. 4. Motor inertia rise again: Set the parameter of rotary speed loop PID correctly. 5. Parameter of speed loop PID is set abnormally: Set the parameter of rotary speed loop PID correctly.
What to do if Parker Controller shows Current Zero Excursion Malfunction?
If your Parker Controller shows a 'Current Zero Excursion Malfunction', check the flat cable. If the issue persists, contact Parker.
How to fix communication timeout on Parker 10G-46-0600-BF Controller?
To fix a communication timeout on your Parker Controller, check whether the communication line is connected reliably.
What causes the wrong direction of motor running on a Parker Controller?
If the motor is running in the wrong direction with your Parker Controller, check if the U, V, W wiring is correct and ensure the parameters are set correctly.
What does 'Line Disconnected' mean on my Parker Controller?
If your Parker Controller displays 'Line Disconnected', it indicates that the analog signal line is disconnected or the signal source is broken. Try changing the signal line or the signal source.
What causes a Parker 10G-46-0600-BF to have output phase loss?
An output phase loss in your Parker Controller could be due to a broken motor, loose motor wires, or a broken inverter. Check if the motor is broken, if the motor wires are loose, and if the inverter is broken.
What to do if my Parker Controller trips the power?
If your Parker Controller is tripping the power, it might be because the wiring current is too high. Check the input wiring, select a matching air switch, reduce the load, and check for any inverter malfunctions.