Effective: December, 2014
Document Number: 88-032500-01A
IPA Intelligent Parker Amplifier
Hardware Installation Guide

Table of Contents

Questions and Answers

  • M
    Monica PachecoAug 17, 2025
    What to do if the Parker IPA-15HC shows a 'Continuous Current = 0' error?
    • S
      sarah66Aug 17, 2025
      To correct the error with the Parker Controller, you must set a non-zero value for continuous current. Refer to your motor specifications for the correct value (C1 Continuous Current).
  • M
    Michael WhiteAug 20, 2025
    How to fix 'Resistance = 0' error on Parker IPA-15HC Controller?
    • B
      Bradley EvansAug 20, 2025
      To fix the issue, set a non-zero value for motor winding resistance in your Parker Controller settings. Refer to your motor specifications for the correct value (C7 Motor Winding Resistance).
  • S
    Sandra ScottAug 22, 2025
    How to resolve 'Rated Speed = 0' error on Parker Controller?
    • C
      Christopher CarterAug 23, 2025
      To resolve the 'Rated Speed = 0' error on your Parker Controller, you need to set a non-zero value for the motor rated speed. Please refer to your motor specifications for the correct value (C8 Motor Rated Speed).
  • E
    Elizabeth DanielAug 26, 2025
    How do I fix the 'Max Inductance = 0' error on my Parker Controller?
    • H
      Hannah SteinAug 26, 2025
      To fix the 'Max Inductance = 0' error on your Parker Controller, you must set a non-zero value. Refer to your motor specifications for the correct value (C4 Motor Inductance).
  • R
    Robyn WrightAug 28, 2025
    How to fix the 'Ke = 0' error on a Parker Controller?
    • J
      jonesbrandyAug 28, 2025
      To correct the 'Ke = 0' error for your Parker Controller, set a non-zero value. Refer to your motor specifications for the correct value (C15 Motor Ke).
  • A
    ajohnsonAug 31, 2025
    Why is the Ethernet Network Status LED off on my Parker IPA-15HC Controller?
    • J
      Joshua MartinezAug 31, 2025
      If the Ethernet Network Status LED is off on your Parker Controller, verify that no two drive/controllers on the network have the same IP address. The IP address is determined by the Address Switch settings on the front panel of the unit. Also, using a standard Ethernet connection, test the IP assignment. At a DOS or command prompt, type 'ping 192.168.100.xx', where xx is the setting of the IPA address switches on the front panel. If you see a 'timeout' message, then the unit is properly configured and is network accessible. Re-attach the Ethernet cable. If a 'timeout' message is seen, the IPA has an invalid IP address. Change the address switches to the correct address and cycle power.
  • M
    Michael SchmidtSep 2, 2025
    What does 'Motor Configuration Warning' mean on my Parker IPA-15HC Controller?
    • Y
      Yolanda HoltSep 2, 2025
      If you receive a Motor Configuration Warning on your Parker Controller, it means the motor rating is too high for the drive/controller, and the drive/controller is using its own limits for safety reasons.
  • H
    Hannah RogersSep 5, 2025
    What to do if I see a 'Motor Configuration Error' on my Parker Controller?
    • M
      Michele RhodesSep 5, 2025
      If you get a Motor Configuration Error on your Parker Controller, it means that one of the motor parameters is set to zero (0). Look at the additional errors to find which parameters are set at zero (0). Refer to your motor specifications for the correct value.
  • J
    Joseph LopezSep 12, 2025
    How to prevent noise on Hall signals in Parker IPA-15HC Controller?
    • Y
      Yvette LewisSep 12, 2025
      If you encounter noise on the Hall signals in your Parker Controller setup, keep high power cables away from low power cables (such as the feedback cable). If they need to cross, cross at right angles.
  • J
    James KingSep 13, 2025
    Why are neither RJ-45 Ethernet Status LEDs illuminated on my Parker IPA-15HC?
    • D
      Diane MatthewsSep 13, 2025
      If neither RJ-45 Ethernet Status LED is illuminated on your Parker Controller, verify that you are using the correct type of cable. Verify that the cable pinout matches the drive’s connector pin out. Try swapping cables with Ethernet cables you know to be good. Even cables that do not meet the Ethernet cable specification should cause the LEDs to illuminate. If the LEDs still do not illuminate, look for Ethernet hardware problems.

Summary

Mechanical Installation of IPA Drives

Electrical Installation Procedures

Installation Safety Requirements

Outlines safety requirements for IPA installation per LVD and EMC directives.

Electrical Installation Precautions

Details precautions for installation, including ESD and circuit breaker use.

IPA Connectors

Identifies and shows the location of all IPA connectors.

IPA Power Supply Requirements

Specifies input power requirements and fuse recommendations for IPA.

IPA Communications Setup

Ethernet Connector Pinout and LEDs

Shows Ethernet connector pinout and explains RJ-45 LED status indicators.

Assigning IP Addresses for IPA

Guides on setting the IPA's IP address using rotary switches.

Setting PC IP Address and Subnet Mask

Provides steps for configuring the PC's IP address for network communication.

Troubleshooting IPA Drive Issues

General Troubleshooting Guidelines

Provides general guidance for troubleshooting IPA drive malfunctions.

Troubleshooting IPA Power Issues

Guides for diagnosing and resolving power-related problems with the IPA.

Troubleshooting IPA Communications

Steps for diagnosing and resolving Ethernet communication problems.

Troubleshooting IPA Motor Control

Guides for examining IPA drive/controller status LEDs for motor control issues.

IPA Error Codes and Resolutions

Lists IPA error codes and provides brief descriptions of corrective actions.

Troubleshooting IPA Hall Sensors

Provides a checklist and potential problems for resolving Hall sensor faults.

Torque Enable Safety Circuitry

Torque Enable Functional Description

Explains the dual hardware channels for preventing drive rotational force.

IPA Torque Enable User Connections

Details the connections for Torque Enable inputs on the Auxiliary connector.

IPA Torque Enable Fault Operation

Details fault detection when TRQ_EN1 and TRQ_EN2 are in opposite states.

Additional Specifications for IPA

IPA Protective Circuits

Covers short circuit, over-temperature, under-voltage, and over-voltage protection.

IPA Short Circuit Protection

Explains the drive's protection against short circuits.

IPA Drive;Controller Over-Temperature Protection

Details the over-temperature monitoring and fault reset procedures.

IPA Under-Voltage Protection

Describes the under-voltage protection and fault clearing.

IPA Over-Voltage Protection

Explains over-voltage protection against excessive regeneration.

Regulatory Compliance UL and CE

General Safety Considerations for IPA

Safety procedures for IPA installation based on local regulations and IEC 61010-1.

Installing the IPA Drive

Guidelines for installation by qualified technicians, including enclosure use.

Appendix B: IPA with IForce or Ripped Linear Servos

Parker IPA-15HC Specifications

General IconGeneral
Output Current15 A
Output Voltage24 VDC
Power Rating360 W
Storage Temperature85 °C
Humidity5% to 95% non-condensing