ELECTRICAL INSTALLATION
46 IPA Hardware Installation Guide
Separate Sources Connections
Figure 15 shows how to connect separate external Motor and Control Power sources to the terminal connector
installed in the drive.
IMPORTANT: You must remove the factory installed jumper wires to use separate
power sources. For more information on the jumpers, see Factory
Installed Jumpers on page 30.
Figure 15. - Motor and Control Power Supply Connection, Separate Sources
Warning: You must connect the drive’s protective conductor terminal,
marked with the earth symbol , to a reliable system
Protective Earth.
Warning: The drive’s connector strip terminals have hazardous voltages
when power is applied to the drive, and up to several minutes
after power is removed. Lower voltages may still be present for
several minutes after power is removed. During normal
operation, these high voltage terminals must not be accessible
to the user.
Multiple inputs (remove jumpers)
Connections
Connect Motor Input Power
L1, L2, Gnd
- and -
Connect Control Input Power
C1, C2, Gnd

Table of Contents