ELECTRICAL INSTALLATION
30 IPA Hardware Installation Guide
Factory Installed Jumpers
The IPA comes with external jumpers installed in the Input Power / Mains connector from C1 to L1, and C2 to L2.
Figure 7 shows the location of the factory installed jumpers.
Figure 7. - Factory-Installed Jumpers on Input Power/Mains Connector
X6 Motor Feedback Connector
Inputs for the encoder feedback, motor thermal switch, and hall effects are located on the 15-pin Motor Feedback
connector.
Figure 8. - Motor Feedback Connector, Female
Motor Feedback Connector Specification
Description
Specification
Connector Type
15-Pin High Density
D-Subminiature
(female socket)
Manufacturer
KYCON or equivalent
KYCON Part Number
K66-E15S-NR